Setting
2.14.5
Setting of UVS_MV (Function ID: 471181)
Setting device
BLK
UVSBLK-EN
UVSBLK
TUVBLK
UVS1-EN
UVS2-EN
UVS3-EN
UVS4-EN
UVS1
UVS1-Timer
DT
UVS1
UVS1-DPR
TUVS1
IDMT
UVS1
UVS1-DPR
UVS1-TMS
TUVS1R
ORG
UVS1
UVS1-DPR
UVS1-TMS
TUVS1R
Output
UVS1-VTFBlk
UVS1-UseFor
UVS2
UVS2-Timer
DT
UVS2
UVS2-DPR
TUVS2
IDMT
UVS2
UVS2-DPR
UVS2-TMS
TUVS2R
ORG
UVS2
UVS2-DPR
UVS2-TMS
TUVS2R
Output
UVS2-VTFBlk
UVS2-UseFor
UVS3
UVS3-Timer
DT
UVS3
UVS3-DPR
TUVS3
IDMT
UVS3
UVS3-DPR
UVS3-TMS
TUVS3R
ORG
UVS3
UVS3-DPR
UVS3-TMS
TUVS3R
Output
UVS3-VTFBlk
UVS3-UseFor
UVS4
UVS4-Timer
DT
UVS4
UVS4-DPR
Range
Unit
Off / On
- Operation canceled when UVSBLK operated
5.0 – 20.0
V Threshold of UVSBLK element
0.00 – 300.00
s UVSBLK operation delay timer
Off / On
- UVS1 protection scheme switch
Off / On
- UVS2 protection scheme switch
Off / On
- UVS3 protection scheme switch
Off / On
- UVS4 protection scheme switch
DT / IDMT / Original
- UVS1 delay type
5.0 - 130.0
V UVS1 threshold
100 - 120
% UVS1 drop-out/pick-up ratio
0.00 - 300.00
s UVS1 operating delay time (in DT mode)
5.0 - 130.0
V UVS1 threshold
100 - 120
% UVS1 drop-out/pick-up ratio
0.010 - 100.000
- UVS1 time multiplier (in IDMT mode)
0.0 - 300.0
s UVS1 definite time reset delay
5.0 - 130.0
V UVS1 threshold
100 - 120
% UVS1 drop-out/pick-up ratio
0.010 - 100.000
- UVS1 time multiplier (in ORG mode)
0.0 - 300.0
s UVS1 definite time reset delay
Non / Block
- UVS1 operation block by VTF
Trip / Alarm
- UVS1 used for trip or alarm
DT / IDMT / Original
- UVS2 delay type
5.0 - 130.0
V UVS2 threshold
100 - 120
% UVS2 drop-out/pick-up ratio
0.00 - 300.00
s UVS2 operating delay time (in DT mode)
5.0 - 130.0
V UVS2 threshold
100 - 120
% UVS2 drop-out/pick-up ratio
0.010 - 100.000
- UVS2 time multiplier (in IDMT mode)
0.0 - 300.0
s UVS2 definite time reset delay
5.0 - 130.0
V UVS2 threshold
100 - 120
% UVS2 drop-out/pick-up ratio
0.010 - 100.000
- UVS2 time multiplier (in ORG mode)
0.0 - 300.0
s UVS2 definite time reset delay
Non / Block
- UVS2 operation block by VTF
Trip / Alarm
- UVS2 used for trip or alarm
DT / IDMT / Original
- UVS3 delay type
5.0 - 130.0
V UVS3 threshold
100 - 120
% UVS3 drop-out/pick-up ratio
0.00 - 300.00
s UVS3 operating delay time (in DT mode)
5.0 - 130.0
V UVS3 threshold
100 - 120
% UVS3 drop-out/pick-up ratio
0.010 - 100.000
- UVS3 time multiplier (in IDMT mode)
0.0 - 300.0
s UVS3 definite time reset delay
5.0 - 130.0
V UVS3 threshold
100 - 120
% UVS3 drop-out/pick-up ratio
0.010 - 100.000
- UVS3 time multiplier (in ORG mode)
0.0 - 300.0
s UVS3 definite time reset delay
Non / Block
- UVS3 operation block by VTF
Trip / Alarm
- UVS3 used for trip or alarm
DT / IDMT / Original
- UVS4 delay type
5.0 - 130.0
V UVS4 threshold
100 - 120
% UVS4 drop-out/pick-up ratio
- 161 -
Contents
6F2T0207 (0.01)
Default
Note
Off
10.0
10.00
Off
Off
Off
Off
DT
60.0
100
1.00
60.0
100
1.000
0.0
60.0
100
1.000
0.0
Non
Trip
DT
60.0
100
1.00
60.0
100
1.000
0.0
60.0
100
1.000
0.0
Non
Trip
DT
60.0
100
1.00
60.0
100
1.000
0.0
60.0
100
1.000
0.0
Non
Trip
DT
60.0
100
GRE200 (5,6)