Setting
2.4.9
SEF_MV (Function ID: 442081)
Setting items
SEF1
SEF1-EN
SEF1 Directio
SEF1-Dir
n
Pol.
SEF1-Angle
SEF1-Vpol
RP
RP1-EN
RP1
SEF1 characteristic
SEF1-Timer
DT
SEF1
SEF1-DPR
TSEF1
IEC
SEF1
SEF1-DPR
SEF1-TMS-
IEC
TSEF1R
UK
SEF1
SEF1-DPR
SEF1-TMS-UK
TSEF1R
IEEE
SEF1
SEF1-DPR
SEF1-TMS-
IEEE
Rtimer
SEF1-Rtimer
TSEF1R
SEF1-RTMS-
IEEE
US
SEF1
SEF1-DPR
SEF1-TMS-US
Rtimer
SEF1-Rtimer
TSEF1R
SEF1-RTMS-
US
ORG
SEF1
SEF1-DPR
SEF1-TMS-
ORG
SEF1-Rtimer
Rtimer
TSEF1R
SEF1-RTMS-
ORG
SEF1-k
SEF1-a
SEF1-c
SEF1-kr
SEF1-b
Range
Unit
Off / On
- SEF1 protection enable
NonDir / Forward /
- SEF1 selection of protection direction
Reverse
-90 - 90
deg SEF1 polarizing angle in directional element
3.0
V SEF1 polarizing vol. in directional element
Off / On
- Enabling RP in directional protection
0.00 – 100.00
W Threshold of residual power element
DT / IEC-NI / IEC-VI /
IEC-EI / UK-LTI /
IEEE-MI / IEEE-VI /
- SEF1 delay type
IEEE-EI / US-CO2 /
US-CO8 / Original
0.001 - 1.000
A SEF1 threshold (in DT mode)
10 - 100
% SEF1 drop-out/pick-up ratio
0.00 - 300.00
s SEF1 operating delay time (in DT mode)
0.001 - 1.000
A SEF1 threshold (in IDMT mode)
10 - 100
% SEF1 drop-out/pick-up ratio
0.010 - 50.000
- SEF1 time multiplier of IEC inverse curve
0.00 - 300.00
s SEF1 definite time reset delay
0.001 - 1.000
A SEF1 threshold (in IDMT mode)
10 - 100
% SEF1 drop-out/pick-up ratio
0.010 - 50.000
- SEF1 time multiplier of UK inverse curve
0.00 - 300.00
s SEF1 definite time reset delay
0.001 - 1.000
A SEF1 threshold (in IDMT mode)
10 - 100
% SEF1 drop-out/pick-up ratio
0.010 - 50.000
- SEF1 time multiplier of IEEE inverse curve
DEF / DEP
- SEF1 reset delay type of IEEE
0.00 - 300.00
s SEF1 definite time reset delay
SEF1 dependent reset time multiplier of IEEE
0.010 - 50.000
-
inverse curve
0.001 - 1.000
A SEF1 threshold (in IDMT mode)
10 - 100
% SEF1 drop-out/pick-up ratio
0.010 - 50.000
- SEF1 time multiplier of US inverse curve
DEF / DEP
- SEF1 reset delay type of US
0.00 - 300.00
s SEF1 definite time reset delay
SEF1 dependent reset time multiplier of US
0.010 - 50.000
-
inverse curve
0.001 - 1.000
A SEF1 threshold (in IDMT mode)
10 - 100
% SEF1 drop-out/pick-up ratio
0.010 - 50.000
- SEF1 time multiplier of Original inverse curve
DEF / DEP
- SEF1 reset delay type of ORG
0.00 - 300.00
s SEF1 definite time reset delay
SEF1 dependent reset time multiplier of
0.010 - 50.000
-
Original inverse curve
0.00000 - 500.00000
- SEF1 user original curve coefficient
0.00000 - 10.00000
- SEF1 user original curve coefficient
0.00000 - 10.00000
- SEF1 user original curve coefficient
0.00000 - 500.00000
- SEF1 user original curve coefficient
0.00000 - 10.00000
- SEF1 user original curve coefficient
- 83 -
Contents
6F2T0207 (0.01)
Default
Note
Off
Non
-45
3.0
Off
0.00
DT
0.010
100
1.00
0.010
100
1.000
0.00
0.010
100
1.000
0.00
0.010
100
1.000
DEF
0.00
1.000
0.010
100
1.000
DEF
0.00
1.000
0.010
100
1.000
DEF
0.00
1.000
0.00000
0.00000
0.00000
0.00000
0.00000
GRE200 (5,6)