Table 4.2-4 Mapping points for the reception of control commands
Signal Number
Signal Name
512001 7003016D08
DEV01_CONTROL_REQ
512001 7003026D08
DEV02_CONTROL_REQ
512001 7003036D08
DEV03_CONTROL_REQ
...
...
512001 7003486D08
DEV72_CONTROL_REQ
Signal Number
Signal Name
5A0001 0008001F41
DCB RCV OR
5A0001 0008001F40
Travelling OR
4A1001 8300001B6F
GEN.TRIP
5A0001 3108003F40
SDCEN
5A0101 3100001F43
SERI_ERR
Table 4.2-6 PLC Connection points (Input signals for select condition logic)
Signal Number
Signal Name
512001 810301EE62
DPOS01IN_TMP_32
512001 810302EE62
DPOS02IN_TMP_32
512001 810303EE62
DPOS03IN_TMP_32
....
....
5A0101 801016EF40
DPOS72IN_TMP_32
512001 800301EE61
DPOS01IN_TMP_31
512001 800302EE61
DPOS02IN_TMP_31
512001 800303EE61
DPOS03IN_TMP_31
...
...
512001 800348EE61
DPOS72IN_TMP_31
512001 820301ED50
DPOS01IN_TMP_28
512001 820302ED50
DPOS02IN_TMP_28
512001 820303ED50
DPOS03IN_TMP_28
....
....
512001 820348ED50
DPOS04IN_TMP_28
Table 4.2-7 PLC Monitoring points (Output signal for select condition logic)
Signal Number
Signal Name
512001 8003011F5A
DPOS01_SC_ST_ERR
512001 8003021F5A
DPOS02_SC_ST_ERR
512001 8003031F5A
DPOS03_SC_ST_ERR
....
....
512001 8003481F5A
DPOS72_SC_ST_ERR
512001 8103011F5F
DPOS01_F_QLT_SPP
512001 8103021F5F
DPOS02_F_QLT_SPP
512001 8103031F5F
DPOS03_F_QLT_SPP
....
....
512001 8103481F5F
DPOS72_F_QLT_SPP
512001 8203011F60
DPOS01_F_BI_ERR
512001 8203021F60
DPOS02_F_BI_ERR
512001 8203031F60
DPOS03_F_BI_ERR
....
....
512001 8203481F60
DPOS72_F_BI_ERR
Description
DPOS01 control command received. (Mapping Data)
DPOS02 control command received. (Mapping Data)
DPOS03 control command received. (Mapping Data)
...
DPOS72 control command received. (Mapping Data)
Table 4.2-5 Input signals to condition logic
Description
Double Command Blocking(DCB) is in progress.
Travelling events are detected.
General trip
(This is setting of CMNCTRL)
Serious Error detected
Description
DPOS01 additional failure condition(PLC#1)
DPOS02 additional failure condition(PLC#1)
DPOS03 additional failure condition(PLC#1)
....
DPOS72 additional failure condition(PLC#1)
DPOS01 user configurable select condition(PLC#2)
DPOS02 user configurable select condition(PLC#2)
DPOS03 user configurable select condition(PLC#2)
...
DPOS72 user configurable select condition(PLC#2)
DPOS01 control hierarchy condition(PLC#3)
DPOS02 control hierarchy condition(PLC#3)
DPOS03 control hierarchy condition(PLC#3)
....
DPOS20 control hierarchy condition(PLC#3)
Description
DPOS01 select command mode is invalid.
DPOS02 select command mode is invalid.
DPOS03 select command mode is invalid.
....
DPOS72 select command mode is invalid.
Event suppression detected (DPOS01)
Event suppression detected (DPOS02)
Event suppression detected (DPOS03)
....
Event suppression detected (DPOS72)
BI connection error detected(DPOS01)
BI connection error detected(DPOS02)
BI connection error detected(DPOS03)
....
BI connection error detected(DPOS72)
- 504 -
6F2T0207 (0.01)
M/O
M
M
M
M
M/O
N/A
N/A
N/A
N/A
N/A
M/O
O
O
O
O
O
O
O
O
M
M
M
M
GRE200 (5,6)