2.8 I/O system

2.8.1 Definition of fieldbuses, IRC5

General
The IRC5 Controller may be fitted with a number of different fieldbus adapters and
fieldbus master/slave boards.
In the standard form, no fieldbus is mounted to the controller.
Fieldbus master/slave boards
On the main computer unit there are slots available for installing a master/slave
board.
xx1600000536
A
B
The following master/slave boards are available:
Description
PROFIBUS Master PCIexpress
DeviceNet Master/Slave PCIexpress
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB
Slot for PCIexpress boards
Slot for safety module (option SafeMove Pro or SafeMove Basic)
© Copyright 2007-2024 ABB. All rights reserved.
2 Installation and commissioning
2.8.1 Definition of fieldbuses, IRC5
B
Art. no.
Type designation
3HAC044872-001
DSQC1005
3HAC043383-001
DSQC1006
Continues on next page