Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

2
3
4
5
6
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB
Action
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before hand-
ling the unit read the safety information in
section
The unit is sensitive to ESD on
page
48.
If not already in place, fit the EMC strips on
the SafeMove board.
Connect both SMB cables and both Ether-
net cables to the SafeMove board before
mounting the board. These connections
may be difficult to reach once the board is
mounted.
The two Ethernet connectors on the Safe-
Move board are interchangeable (it does
not matter which is connected to the main
computer and which is connected to the
axis computer).
Refit the SafeMove board and the axis
computer.
Refit all cables.
© Copyright 2007-2024 ABB. All rights reserved.
4.15 Replacement of SafeMove board DSQC 647
Note/illustration
xx0800000204
A: EMC strips
xx0800000103
A: SMB1 cable
B: SMB2 cable
C: Ethernet cables
4 Repair
Continued
Continues on next page