2.5.6 Connecting communication cables between IRC5 Panel Mounted Drive Module and control module
Equipment
Standard toolkit
Circuit diagram
Connecting the Ethernet cable
Use this procedure details connect the Ethernet cable between the drive module
and control module.
1
2
Connecting the Panel board/Contactor interface board cable
Use this procedure to connect the panel board/contactor interface board cable
between the drive module and control module.
1
2
Connecting the AUX contact cable for SafeMove2
Use this procedure to connect the harness AUX contact, XP/XS38, cable between
the drive module and control module.
1
2
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB
Action
Connect the cable to the Axis computer board con-
nector A42.X2, route and strap the cable as shown
in the illustration above.
Connect the cable to the Main computer connector
A32.A9.
Action
Connect the cable to the Contactor interface board
connector A43.X1, route and strap the cable as
shown in the illustration above.
Connect the cable to the Panel board connector
A21.X7.
Action
Connect the cable to the XS38 connector on the
back wall of the control module.
Route and strap the cable as shown in the illustra-
tion above.
© Copyright 2007-2024 ABB. All rights reserved.
2 Installation and commissioning
Art. no.
Note
Described in section Standard
toolkit.
See
Note/Illustration
Note/Illustration
Note/Illustration
Only the cable supplied together
with the SafeMove2 option must
be used.
Continued
Circuit diagrams on page
273.