ABB IRC5 Product Manual page 94

Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

2 Installation and commissioning
2.5.12 Connection of the MOTORS ON/MOTORS OFF circuit
Continued
Technical data
ES1 and ES2 max output voltage
ES1 and ES2 max output current
External supply of ES relay
Rated current per chain
Max. potential in relation to the cabinet earthing
and other signal groups.
Signal class
Connection to operating mode selector
The illustration below shows the connection of terminals for customer use.
xx0500002092
A
Technical data
Max. voltage
Max. current
Max. potential in relation to the cabinet earthing
and other signal groups.
Signal class
94
Mode selector
© Copyright 2007-2024 ABB. All rights reserved.
120 VAC or 48 VDC
120 VAC: 4 A
48 VDC L/R: 50 mA
24 VDC L/R: 2 A
24 VDC R load: 8 A
24 VDC ± 10% between terminals X1:3,
7 and X2:7, 3 respectively.
Note
In case of interference, the external sup-
ply must be properly filtered.
40 mA
300 V
Control signals
48 VDC
4 A
300 V
Control signals