ABB IRC5 Product Manual page 205

Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

PMC large:
xx1100000499
A
B
Removal
The procedure below details how to remove the SafeMove board.
1
2
3
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB
SafeMove board
Axis computer
Action
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more in-
formation, see
Electrical safety on page
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before hand-
ling the unit read the safety information in
section
The unit is sensitive to ESD on
page
48.
Disconnect the cables connected to the
SafeMove board and the cables between
the SafeMove board and the axis com-
puter.