For the overall design and structure, the category 3 has been verified and meeting
the requirements of CCF.
Each of the stop circuits includes different components like enabling switch, panel
board, contactor board, relays etc. For each of these the MTTF
calculated according to EN ISO 13849-1 Annex C, D and E resulting in the values
as specified in the following table.
See the SISTEMA/ABB FSDT libraries for details of the safety functions.
IRC5 Single and IRC5 Panel Mounted Controller
Safety function
Emergency stop inputs (operator panel)
Automatic stop input
General stop input
Superior stop input
Limiting switch input
(without customer connection)
Three-position enabling device inputs
Emergency stop status outputs
Emergency stop inputs (source external)
SafeMove (option) (without customer connections)
Electronic Position Switches (option) (without
customer connections)
SafeMove2 functions (option)
Protective stop
Emergency stop
Emergency stop safe fieldbus output
Speed supervision
Speed supervision safe fieldbus output
Position supervision
Position supervision safe fieldbus output
External power control
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB
Emergency stop on FlexPendant
Limiting robot motion
Protective stops
SafeMove
EPS
SafeMove2
© Copyright 2007-2024 ABB. All rights reserved.
1.1.2 Safety data
and DC have been
D
Calculated MTTF
DC
D
avg
[years]
112
Medium
120
Medium
120
Medium
120
Medium
176
Medium
91
Medium
239
Medium
101
Medium
58
Medium
105
Medium
370
Low
370
Low
370
Low
370
Low
370
Low
370
Low
370
Low
88
Low