4 Repair
4.22.1 Replacement of customer I/O power supply
Continued
3
4
5
Refitting
The procedure below details how to refit the customer I/O power supply.
1
2
Continues on next page
230
Action
Loosen the DIN-lock fixing screw.
Pull the DIN-lock lever downwards to release the
power supply unit.
Remove the power supply unit.
Action
DANGER
Before doing any work inside the cabinet, discon-
nect the mains power. For more information, see
Electrical safety on page
Refit the new power supply unit on the DIN-rail.
© Copyright 2007-2024 ABB. All rights reserved.
35.
Product manual - IRC5 Panel Mounted Controller
Note/Illustration
xx0700000124
A: DIN-lock fixing screw