The service port is configured with a fixed IP-address, which is the same for all
controllers and cannot be changed, and has a DHCP server that automatically
assigns an IP-address to the connected PC.
WAN port
The WAN port is a public network interface to the controller, typically connected
to the factory network with a public IP address provided by the network
administrator.
The WAN port can be configured with fixed IP-address, or DCHP, from the Boot
application on the FlexPendant. By default the IP-address is blank.
Some network services, like FTP and RobotStudio, are enabled by default. Other
services are enabled by the respective RobotWare application.
LAN ports
The LAN 1 port is dedicated for connecting the FlexPendant.
The LAN 2 and LAN 3 ports are intended for connecting network based process
equipment to the controller. For example field buses, cameras, and welding
equipment.
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB
Note
For more information about connecting a PC to the service port, see section
Connecting a PC to the controller in Operating manual - RobotStudio.
Note
The WAN port cannot use any of the following IP-addresses which are allocated
for other functions on the IRC5 controller:
192.168.125.0 - 255
192.168.126.0 - 255
192.168.127.0 - 255
192.168.128.0 - 255
192.168.129.0 - 255
192.168.130.0 - 255
The WAN port cannot be on a subnet which overlaps with any of the above
reserved IP-addresses. If a subnet mask in the class B range has to be used,
then a private address of class B must be used to avoid any overlapping. Please
contact your local network administrator regarding network overlapping.
See the section about topic Communication in Technical reference
manual - System parameters.
Note
For more information about connecting a PC to the WAN port, see section
Connecting a PC to the controller in Operating manual - RobotStudio.