ABB IRC5 Product Manual page 201

Panel mounted controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

3
4
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB
4.14 Replacement of EPS board DSQC 646 for Electronic Position Switches
Action
Disconnect the following cables connected
to the EPS board and axis computer:
Plug contact in I/O connector
Power cables
SMB cables
Ethernet cables
Remove the attachment screws of the axis
computer and remove the axis computer.
© Copyright 2007-2024 ABB. All rights reserved.
Note/illustration
B
C
xx0700000101
A: Plug contact in I/O connector
B: Power cables
C: SMB cables
D: Ethernet cables
xx0900000030
A: axis computer
B: attachment screws
Continues on next page
4 Repair
Continued
A
D
201

Advertisement

Table of Contents
loading

Table of Contents