3
4
Product manual - IRC5 Panel Mounted Controller
3HAC047137-001 Revision: AB
4.14 Replacement of EPS board DSQC 646 for Electronic Position Switches
Action
Disconnect the following cables connected
to the EPS board and axis computer:
•
Plug contact in I/O connector
•
Power cables
•
SMB cables
•
Ethernet cables
Remove the attachment screws of the axis
computer and remove the axis computer.
© Copyright 2007-2024 ABB. All rights reserved.
Note/illustration
B
C
xx0700000101
A: Plug contact in I/O connector
B: Power cables
C: SMB cables
D: Ethernet cables
xx0900000030
•
A: axis computer
•
B: attachment screws
Continues on next page
4 Repair
Continued
A
D
201