296 Parameters
No.
Name/Value
30.12
Maximum speed
-30000.00 ...
30000.00 rpm
30.13
Minimum frequency
-500.00 ... 500.00
Hz
30.14
Maximum
frequency
-500.00 ... 500.00
Hz
30.15
Maximum start
current enable
Disable
Enable
30.16
Maximum start
current
0.00 ... 30000.00 A
30.17
Maximum current
0.00 ... 30000.00 A
Description
Defines the maximum allowed speed.
WARNING! This value must not be lower than
Minimum
speed.
WARNING! In frequency control mode, this limit is not
effective. Make sure the frequency limits
30.14) are set appropriately if frequency control is
used.
WARNING! In a master/follower configuration, do not
set maximum and minimum speed limits with the
same sign on a follower drive. See section
Master/follower functionality
Maximum speed.
Defines the minimum allowed frequency.
WARNING! This value must not be higher than
Maximum
frequency.
WARNING! This limit is effective in frequency control
mode only.
Minimum frequency.
Defines the maximum allowed frequency.
WARNING! This value must not be lower than
Minimum
frequency.
WARNING! This limit is effective in frequency control
mode only.
Maximum frequency.
A temporary motor current limit specifically for starting can be
defined by this parameter and
When this parameter is set to Enable, the drive observes the
start current limit defined by
The limit is in force for 2 seconds after initial magnetization (of
an asynchronous induction motor) or autophasing (of a
permanent magnet motor), but not more often than once in
every 7 seconds. Otherwise, the limit defined by
Maximum current
is in force.
Note: The availability of a start current higher than the
general limit depends on drive hardware.
Start current limit disabled.
Start current limit enabled.
Defines a maximum start current when enabled by parameter
30.15 Maximum start current
Maximum start current.
Defines the maximum allowed motor current.
Maximum motor current.
(30.13
(page 68).
30.16 Maximum start
30.16 Maximum start
current.
30.17
enable.
Def/FbEq16
1500.00 rpm;
1800.00 rpm
30.11
(95.20
b0)
and
See par.
46.01
-50.00 Hz;
-60.00 Hz
30.14
(95.20
b0)
See par.
46.02
50.00 Hz;
60.00 Hz
30.13
(95.20
b0)
See par.
46.02
Disable
current.
0
1
-
1 = 1 A
0.00 A
1 = 1 A

Hide quick links: