204 Parameters
No.
Name/Value
13.28
AO2 source max
-32768.0 ...
32767.0
13.29
AO2 out at AO2 src
min
0.000 ... 22.000 mA Minimum AO2 output value.
13.30
AO2 out at AO2 src
max
0.000 ... 22.000 mA Maximum AO2 output value.
13.91
AO1 data storage
-327.68 ... 327.67
13.92
AO2 data storage
-327.68 ... 327.67
14
14 I/O extension
module 1
14.01
Module 1 type
None
FIO-01
FIO-11
FDIO-01
FAIO-01
14.02
Module 1 location
Slot 1
Slot 2
Slot 3
4...254
Description
Defines the real maximum value of the signal (selected by
parameter
13.22 AO2
source) that corresponds to the
maximum required AO2 output value (defined by parameter
13.30 AO2 out at AO2 src
source
min.
Real signal value corresponding to maximum AO2 output
value.
Defines the minimum output value for analog output AO2.
See also drawing at parameter
Defines the maximum output value for analog output AO2.
See also drawing at parameter
Storage parameter for controlling analog output AO1 eg.
through fieldbus.
In
13.12 AO1
source, select
parameter as the target of the incoming value data.
With the embedded fieldbus interface, simply set the target
selection parameter of that particular data (58.101...58.124)
to
AO1 data
storage.
Storage parameter for AO1.
Storage parameter for controlling analog output AO2 eg.
through fieldbus.
In
13.22 AO2
source, select
parameter as the target of the incoming value data.
With the embedded fieldbus interface, simply set the target
selection parameter of that particular data (58.101...58.124)
to
AO2 data
storage.
Storage parameter for AO2.
Configuration of I/O extension module 1.
See also section
Programmable I/O extensions
Note: The contents of the parameter group vary according to
the selected I/O extension module type.
Activates (and specifies the type of) I/O extension module 1.
Inactive.
FIO-01.
FIO-11.
FDIO-01.
FAIO-01.
Specifies the slot (1...3) on the control unit of the drive into
which the I/O extension module is installed. Alternatively,
specifies the node ID of the slot on an FEA-03 extension
adapter.
Slot 1.
Slot 2.
Slot 3.
Node ID of the slot on the FEA-03 extension adapter.
max). See parameter
13.27 AO2
13.27 AO2 source
13.27 AO2 source
AO1 data
storage. Then set this
AO2 data
storage. Then set this
(page 65).
Def/FbEq16
100.0
1 = 1
0.000 mA
min.
1000 = 1 mA
20.000 mA
min.
1000 = 1 mA
0.00
100 = 1
0.00
100 = 1
None
0
1
2
3
4
Slot 1
1
2
3
1 = 1