No.
Name
40.03
Process PID setpoint actual
40.04
Process PID deviation actual
40.05
Process PID trim output act
40.06
Process PID status word
40.07
Set 1 PID operation mode
40.08
Set 1 feedback 1 source
40.09
Set 1 feedback 2 source
40.10
Set 1 feedback function
40.11
Set 1 feedback filter time
40.12
Set 1 unit selection
40.14
Set 1 setpoint scaling
40.15
Set 1 output scaling
40.16
Set 1 setpoint 1 source
40.17
Set 1 setpoint 2 source
40.18
Set 1 setpoint function
40.19
Set 1 internal setpoint sel1
40.20
Set 1 internal setpoint sel2
40.21
Set 1 internal setpoint 1
40.22
Set 1 internal setpoint 2
40.23
Set 1 internal setpoint 3
40.24
Set 1 internal setpoint 4
40.25
Set 1 setpoint selection
40.26
Set 1 setpoint min
40.27
Set 1 setpoint max
40.28
Set 1 setpoint increase time
40.29
Set 1 setpoint decrease time
40.30
Set 1 setpoint freeze enable
40.31
Set 1 deviation inversion
40.32
Set 1 gain
40.33
Set 1 integration time
Type
Range
Real
-32768.00 ... 32767.00
Real
-32768.00 ... 32767.00
Real
-32768.00 ... 32767.00
PB
0000h...FFFFh
List
0...2
Analog
-
src
Analog
-
src
List
0...11
Real
0.000 ... 30.000
List
0...2
Real
-32768.00 ... 32767.00
Real
-32768.00 ... 32767.00
Analog
-
src
Analog
-
src
List
0...11
Binary
-
src
Binary
-
src
Real
-32768.00 ... 32767.00
Real
-32768.00 ... 32767.00
Real
-32768.00 ... 32767.00
Real
-32768.00 ... 32767.00
Binary
-
src
Real
-32768.00 ... 32767.00
Real
-32768.00 ... 32767.00
Real
0.0 ... 1800.0
Real
0.0 ... 1800.0
Binary
-
src
Binary
-
src
Real
0.10 ... 100.00
Real
0.0 ... 32767.0
Additional parameter data 535
Unit
rpm, % or
Hz
rpm, % or
Hz
rpm, % or
Hz
-
-
-
-
-
s
-
-
-
-
-
-
-
-
rpm, % or
Hz
rpm, % or
Hz
rpm, % or
Hz
rpm, % or
Hz
-
-
-
s
s
-
-
-
s
FbEq32
100 = 1 rpm, %
or Hz
100 = 1 rpm, %
or Hz
100 = 1 rpm, %
or Hz
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1000 = 1 s
1 = 1
100 = 1
100 = 1
1 = 1
1 = 1
1 = 1
1 = 1
1 = 1
100 = 1 rpm, %
or Hz
100 = 1 rpm, %
or Hz
100 = 1 rpm, %
or Hz
100 = 1 rpm, %
or Hz
1 = 1
100 = 1
100 = 1
10 = 1 s
10 = 1 s
1 = 1
1 = 1
100 = 1
10 = 1 s