444 Parameters
No.
Name/Value
81.40
Cleaning abort
source
Not selected
Selected
DI1
DI2
DI3
DI4
DI5
DI6
DIO1
DIO2
Other
81.41
Supervision low
signal src
NULL
AI1 scaled
AI2 scaled
FBA1 ref
FBA2 ref
EFB1 ref
EFB2 ref
Estimated motor
current
Motor current%
Other
81.42
Supervision low
limit
0.00...30000.00
81.43
Supervision low
delay
0.0...3200.0 s
Description
Defines source for the cleaning abort command.
The cleaning operation can be interrupted at any time with
abort command. In such case, ESP control program will
immediately switch to production mode.
Cleaning abort source is not selected.
Cleaning abort source is selected.
Digital input DI1
(10.02 DI delayed
Digital input DI2
(10.02 DI delayed
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
Digital input/output DIO1
Digital input/output DIO2
Source selection (see
Terms and abbreviations
Defines the source for the supervision low signal.
The value from this parameter is then compared with the limit
set in parameter
81.42 Supervision low
signal is lower than the limit for the time period set in
parameter
81.43 Supervision low
procedure is interrupted. The ESP control program will
immediately switch to production mode. The supervision low
is not active during off-time period.
Note: For the supervision low function to work, parameter
81.02 Pump cleaning option sel
Zero
See parameter
12.12 AI1 scaled value
See parameter
12.22 AI2 scaled value
See parameter
03.05 FB A reference 1
See parameter
03.06 FB A reference 2
See parameter
03.09 EFB reference 1
See parameter
03.10 EFB reference 2
Parameter
09.13 Motor current estimated
Estimated motor current in % of nominal motor current.
Source selection (see
Terms and abbreviations
Defines low limit value for the Supervision low function.
See parameter
81.41 Supervision low signal
Supervision low limit.
Defines delay time for the Supervision low function.
See parameter
81.41 Supervision low signal
Supervision low delay.
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
(11.02 DIO delayed
status, bit 0).
(11.02 DIO delayed
status, bit 1).
on page 148). -
limit. If the observed
delay, then cleaning
bit-11 must be set to 1.
(see page 197).
(see page 199).
(page 156).
(page 156).
(page 156).
(page 156).
(see page 183).
on page 148). -
src.
src.
Def/FbEq16
Not selected
0
1
2
3
4
5
6
7
8
9
Motor
current%
0
1
2
3
4
5
6
7
8
0.00
10 = 1
10.0
10 = 1s

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents