ABB +N5600 Firmware Instructions page 583

Single drive
Table of Contents

Advertisement

Code
Warning
(hex)
A889
Edge counter 2
(Editable message text)
Programmable warning:
33.45 Edge counter 2
warn message
A88A
Value counter 1
(Editable message text)
Programmable warning:
33.55 Value counter 1
warn message
A88B
Value counter 2
(Editable message text)
Programmable warning:
33.65 Value counter 2
warn message
A88C
Device clean
A88D
DC capacitor
A88E
Cabinet fan
A88F
Cooling fan
A890
Additional cooling
A8A0
AI supervision
Programmable warning:
12.03 AI supervision
function
A8B0
Signal supervision
(Editable message text)
Programmable warning:
32.06 Supervision 1 action
A8B1
Signal supervision 2
(Editable message text)
Programmable warning:
32.16 Supervision 2 action
A8B2
Signal supervision 3
(Editable message text)
Programmable warning:
32.26 Supervision 3 action
A8BE
ULC overload warning
Programmable fault:
37.03 ULC overload
actions
Cause
Warning generated by edge
counter 2.
Warning generated by value
counter 1.
Warning generated by value
counter 2.
Warning generated by an on-
time timer.
Programmable warnings:
33.14 On-time 1 warn message
33.24 On-time 2 warn message
An analog signal is outside the
limits specified for the analog
input.
Warning generated by the
signal supervision 1 function.
Warning generated by the
signal supervision 2 function.
Warning generated by the
signal supervision 3 function.
Selected signal has exceeded
the user overload curve.
Fault tracing 583
What to do
Check the source of the warning
(parameter
33.43 Edge counter 2
source).
Check the source of the warning
(parameter
33.53 Value counter 1
source).
Check the source of the warning
(parameter
33.63 Value counter 2
source).
Check the auxiliary code. Check the
source of the warning corresponding to
the code:
0:
33.13 On-time 1 source
1:
33.23 On-time 2 source
10:
05.04 Fan on-time
counter.
Check the auxiliary code (format XYY).
"X" specifies the location of the input (0:
AI on control unit; 1: I/O extension
module 1, etc.), "YY" specifies the input
and limit (01: AI1 under minimum,
02: AI1 over maximum, 03: AI2 under
minimum, 04: AI2 over maximum).
Check signal level at the analog input.
Check the wiring connected to the input.
Check the minimum and maximum limits
of the input in parameter group
Standard
AI,
14 I/O extension module
15 I/O extension module 2
extension module
3.
Check the source of the warning
(parameter
32.07 Supervision 1
Check the source of the warning
(parameter
32.17 Supervision 2
Check the source of the warning
(parameter
32.27 Supervision 3
Check for any operating conditions
increasing the monitored signal (for
example, the loading of the motor if the
torque or current is being monitored).
Check the definition of the load curve
(parameter group
37 User load
12
1,
or
16 I/O
signal).
signal).
signal).
curve).