ABB +N5600 Firmware Instructions page 432

Single drive
Table of Contents

Advertisement

432 Parameters
No.
Name/Value
79.19
Underload event
reaction
Not selected
Warning
Warning with
shutdown
Fault
URT Recovery -
Warning
URT Recovery -
Fault
79.21
Underload curve
point 1
-30000.00...
30000.00
79.22
Underload curve
point 2
-30000.00...
30000.00
79.23
Underload curve
point 3
-30000.00...
30000.00
79.24
Underload curve
point 4
-30000.00...
30000.00
79.25
Underload curve
point 5
-30000.00...
30000.00
Description
Defines response to the underload condition.
If the underload supervision signal stays under active
underload limit as long as set in defined delay time, then the
underload protection function triggers the reaction defined in
this parameter setting.
Underload event reaction is inactive.
Underload condition triggers the drive event
warning. It will stay on as long as underload condition is
present. Warning will automatically disappear if underload
supervision signal stays above the underload limit for the time
defined in parameter
79.18 Underload delay
Underload condition triggers the drive event
warning and immediate stop command. Drive will stop
according to parameter
Underload condition triggers the drive event
fault which immediately trips the drive.
Underload condition triggers the underload ride through
recovery sequence. In case recovery routine helps, motor
speed returns to production speed. If not, drive generates the
event
D205 Underload
warning. It will stay on as long as
underload condition is present. Warning will automatically
disappear if underload supervision signal stays above the
underload limit for the time defined in parameter
Underload delay
time.
Underload condition triggers the underload ride through
recovery sequence. In case recovery routine helps, motor
speed returns to production speed. If not, drive generates the
D102 Underload
fault which immediately trips the drive.
Defines underload curve point 1 load limit active at
corresponding speed set in parameter
speed point
1.
Underload curve point 1.
Defines underload curve point 2 load limit active at
corresponding speed set in parameter
speed point
2.
Underload curve point 2.
Defines underload curve point 3 load limit active at
corresponding speed set in parameter
speed point
3.
Underload curve point 3.
Defines underload curve point 4 load limit active at
corresponding speed set in parameter
speed point
4.
Underload curve point 4.
Defines underload curve point 5 load limit active at
corresponding speed set in parameter
speed point
5.
Underload curve point 5.
D205 Underload
time.
D205 Underload
21.03 Stop mode
setting.
D102 Underload
79.01 Load curve
79.02 Load curve
79.03 Load curve
79.04 Load curve
79.05 Load curve
Def/FbEq16
Warning
0
1
2
3
4
79.18
5
0.00
10 = 1
0.00
10 = 1
0.00
10 = 1
0.00
10 = 1
0.00
10 = 1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents