ABB +N5600 Firmware Instructions page 375

Single drive
Table of Contents

Advertisement

No.
Name/Value
Frequency
50.05
FBA A ref2 type
50.07
FBA A actual 1 type
Auto
Transparent
General
Torque
Speed
Frequency
Position
50.08
FBA A actual 2 type
50.09
FBA A SW
transparent source
Not selected
Other
50.10
FBA A act1
transparent source
Not selected
Other
50.11
FBA A act2
transparent source
Not selected
Other
Description
The scaling is defined by parameter
Selects the type and scaling of reference 2 received from
fieldbus adapter A.
See parameter
50.04 FBA A ref1
Selects the type/source and scaling of actual value 1
transmitted to the fieldbus network through fieldbus adapter
A.
Note: Fieldbus-specific communication profiles may use
different scalings. For more information, see the manual of
the fieldbus adapter.
Type/source and scaling follow the type of reference 1
selected by parameter
50.04 FBA A ref1
individual settings below for the sources and scalings.
The value selected by parameter
transparent source
is sent as actual value 1. No scaling is
applied (the 16-bit scaling is 1 = 1 unit).
The value selected by parameter
transparent source
is sent as actual value 1 with a 16-bit
scaling of 100 = 1 unit (ie. integer and two decimals).
01.10 Motor torque
is sent as actual value 1. The scaling is
defined by parameter
46.03 Torque
01.01 Motor speed used
is defined by parameter
01.06 Output frequency
is defined by parameter
Motor position is sent as actual value 1. See parameter
Motor position
scaled.
Selects the type/source and scaling of actual value 2
transmitted to the fieldbus network through fieldbus adapter
A.
See parameter
50.07 FBA A actual 1
Selects the source of the fieldbus status word when the
fieldbus adapter is set to a transparent communication profile
eg. by its configuration parameters (group
No source selected.
Source selection (see
Terms and abbreviations
When parameter
50.07 FBA A actual 1 type
Transparent
or General, this parameter selects the source of
actual value 1 transmitted to the fieldbus network through
fieldbus adapter A.
No source selected.
Source selection (see
Terms and abbreviations
When parameter
50.08 FBA A actual 2 type
Transparent
or General, this parameter selects the source of
actual value 2 transmitted to the fieldbus network through
fieldbus adapter A.
No source selected.
Source selection (see
Terms and abbreviations
46.02 Frequency
type.
type. See the
50.10 FBA A act1
50.10 FBA A act1
scaling.
is sent as actual value 1. The scaling
46.01 Speed
scaling.
is sent as actual value 1. The scaling
46.02 Frequency
scaling.
type.
51 FBA A
on page 148). -
is set to
on page 148). -
is set to
on page 148). -
Parameters 375
Def/FbEq16
scaling. 5
Auto
Auto
0
1
2
3
4
5
90.06
6
Auto
Not selected
settings).
-
Not selected
-
Not selected
-