346 Parameters
No.
Name/Value
40.25
Set 1 setpoint
selection
Setpoint source 1
Setpoint source 2
DI1
DI2
DI3
DI4
DI5
DI6
DIO1
DIO2
Other [bit]
40.26
Set 1 setpoint min
-32768.00 ...
32767.00
40.27
Set 1 setpoint max
-32768.00 ...
32767.00
40.28
Set 1 setpoint
increase time
0.0 ... 1800.0 s
40.29
Set 1 setpoint
decrease time
0.0 ... 1800.0 s
40.30
Set 1 setpoint
freeze enable
Not selected
Selected
DI1
DI2
DI3
DI4
DI5
DI6
Description
Configures the selection between setpoint sources 1 (40.16)
and 2 (40.17).
This parameter is only effective when parameter
setpoint function
is set to
0 = Setpoint source 1
1 = Setpoint source 2
0.
1.
Digital input DI1
(10.02 DI delayed
Digital input DI2
(10.02 DI delayed
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
Digital input/output DIO1
Digital input/output DIO2
Source selection (see
Terms and abbreviations
Defines a minimum limit for the process PID controller
setpoint.
Minimum limit for process PID controller setpoint.
Defines a maximum limit for the process PID controller
setpoint.
Maximum limit for process PID controller setpoint.
Defines the minimum time it takes for the setpoint to increase
from 0% to 100%.
Setpoint increase time.
Defines the minimum time it takes for the setpoint to decrease
from 100% to 0%.
Setpoint decrease time.
Freezes, or defines a source that can be used to freeze, the
setpoint of the process PID controller. This feature is useful
when the reference is based on a process feedback
connected to an analog input, and the sensor must be
serviced without stopping the process.
1 = Process PID controller setpoint frozen
See also parameter
40.38 Set 1 output freeze
Process PID controller setpoint not frozen.
Process PID controller setpoint frozen.
Digital input DI1
(10.02 DI delayed
Digital input DI2
(10.02 DI delayed
Digital input DI3
(10.02 DI delayed
Digital input DI4
(10.02 DI delayed
Digital input DI5
(10.02 DI delayed
Digital input DI6
(10.02 DI delayed
40.18 Set 1
In1 or
In2.
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
(11.02 DIO delayed
status, bit 0).
(11.02 DIO delayed
status, bit 1).
on page 148). -
enable.
status, bit 0).
status, bit 1).
status, bit 2).
status, bit 3).
status, bit 4).
status, bit 5).
Def/FbEq16
Setpoint
source 1
0
1
2
3
4
5
6
7
10
11
0.00
1 = 1
32767.00
1 = 1
0.0 s
1 = 1
0.0 s
1 = 1
Not selected
0
1
2
3
4
5
6
7

Hide quick links: