Step 4 Configure the pass-through services of NE4. Refer to
services of NE4. The method and parameters for configuring the pass-through services of NE4
are the same as the method and parameters for configuring the pass-through services of NE2.
Step 5 Check whether the services are configured correctly. For details, see Verifying the Correctness
of the SDH Service Configuration.
Step 6 Enable the performance monitoring function of the NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 7 Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Relevant Task
If the services are configured incorrectly and thus need to be deleted, see Deleting SDH Services.

3.8.4 End-to-End Configuration Process

SNCP protection and services on an SNCP ring are configured on the U2000 at the same time.
To configure SNCP services on the source and sink NEs, determine the source boards and
timeslots for the working service and protection service, and configure pass-through services on
the intermediate nodes. The following part describes how to configure services on an SNCP ring
in an end-to-end manner.
Issue 02 (2011-06-30)
Parameter
Value in
This
Example
Source VC4
VC4-1
Source
1-5
Timeslot
Range(e.g.
1,3-6)
Sink Slot
1-SL1D-1
(SDH-1)
Sink VC4
VC4-1
Sink
1-5
Timeslot
Range(e.g.
1,3-6)
Activate
Yes
Immediately
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Description
In this example, the services require five VC-12s.
Source VC4 is set to VC4-1, because a VC-4 contains
63 VC-12s.
In this example, the total capacity of the services is 5xE1
according to the plan. The service level is VC12. Hence,
Source Timeslot Range(e.g.1,3-6) is set to 1-5. See
Figure
3-14.
In this example, the SL1D board in slot 1 is configured
as the sink line board. See
different sink boards depending on the actual situation.
In this example, the services require five VC-12s. Sink
VC4 is set to VC4-1, because a VC-4 contains 63
VC-12s.
In this example, the total capacity of the services is 5xE1
according to the plan. The service level is VC12. Hence,
Sink Timeslot Range(e.g.1,3-6) is set to 1-5. See
Figure
3-14.
-
Step 3
and configure the pass-through
3 Configuring SDH Services
Figure
3-14. You can select
3-49