Step 2 Repeat
service planning.
Step 3 Check whether the services between user A1 and user A2 and the services between user B1 and
user B2 are proper. For details, see Testing Ethernet Service Channels.
Step 4 Enable the performance monitoring function of the NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 5 Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Related Task
If the services are configured incorrectly, see
for the deletion method.

4.6 Configuring PORT-Shared EVPL (VLAN) Services

The PORT-shared EVPL (VLAN) service is applicable when the services of multiple users
received from the same external port on the Ethernet board at a station are transmitted on different
VCTRUNKs to another station or to another external port of the station.

4.6.1 Networking Diagram

The services of multiple users received from the same external port on an Ethernet board of a
station are transmitted to different stations on different VCTRUNKs.

4.6.2 Signal Flow and Timeslot Allocation

Ethernet services wherein different VLAN IDs are used to isolate the data of different users are
received from the same external port of NE1, encapsulated through an internal port, and
transparently transmitted on the SDH network. In this way, the node communicates with a remote
node.
4.6.3 Configuration Process
Ethernet switching boards are required for creating EVPL services of different VLAN IDs on
NE1. In this way, the data of different users received from the same external port can be
Issue 02 (2011-06-30)

Table 4-20 Parameters of port attributes for user A1 and user A2

Parameter
Source NE
Sink NE
Other parameters
l Select Activate the trail and click Finish.
Step 1.2
to
Step 1.3
configure EPL services between user B1 and user B2 according to
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
PORT1
Entry Detection
VCTRUNK1
Entry Detection
PORT1
Entry detection
VCTRUNK1
Entry Detection
5.4.3 Deleting Ethernet Private Line Services