Procedure
Step 1 Configure the EPL services of user A1 and user B1 on NE1.
1.
2.
Issue 02 (2011-06-30)
Set the attributes of the external ports (PORT1 of 3-EGT1 board and PORT1 of the 4-EGT1
board) used by the services of user A1 and user B1.
l In the NE Explorer, select the EGT1 and then choose Configuration > Ethernet
Interface Management > Ethernet Interface from the Function Tree.
l Select External Port.
l Click the Basic Attributes tab. After setting the parameters, click Apply.
Parame
Value in This Example Description
ter
Enabled
PORT1: Enabled
/
Disable
d
Workin
PORT1: Auto-
g Mode
Negotiation
Maximu
PORT1: 1522
m
Frame
Length
MAC
PORT1: Non-Loopback
Loopba
ck
PHY
PORT1: Non-Loopback
Loopba
ck
Set the attributes of the internal ports (VCTRUNK1 of 3-EGT1 board and VCTRUNK1 of
the 4-EGT1 board) used by the services of user A1 and user B1.
l Select Internal Port.
l Click the Encapsulation/Mapping tab. After setting the parameters, click Apply.
Parame
Value in This Example Description
ter
Mappin
VCTRUNK1: GFP
g
Protocol
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Configuring Ethernet Services
PORT1 is used by the service of user A1.
PORT2 is used by the service of user B1. In
this example, Enabled/Disabled is set to
Enabled for PORT1 and PORT2.
In this example, the Ethernet service access
equipment of user A1 and user B1 supports
the auto-negotiation mode. Hence, Working
Mode is set to Auto-Negotiation for PORT1
and PORT2.
Generally, this parameter adopts the default
value 1522.
The MAC loopback setting is used for fault
diagnosis. In this example, MAC
Loopback is set to Non-Loopback.
The PHY loopback setting is used for fault
diagnosis. In this example, PHY Loopback
is set to Non-Loopback.
In this example, the EFS8 board is used. This
parameter adopts the default value GFP.
Mapping Protocol of the VCTRUNKs on
the Ethernet boards of the interconnected
equipment at both ends must be set to the
same value.
4-37