Relationship with Other Parameters
None.
Related Information
According to the position and role of the equipment in the networking, there are three types of
equipment: CE, PE (U-PE & N-PE), and P. Client Edge (CE) indicates the equipment at the
client side. Provider Edge (PE) indicates the edge equipment at the network side. Provider (P)
indicates the intermediate node at the network side.

7.2 Maximum Frame Length (Ethernet Port Attribute)

Description
The Maximum Frame Length (Ethernet Port Attribute) parameter specifies the maximum
frame length that is supported at an Ethernet port.
Impact on the System
If the packet length exceeds the specified maximum frame length, the packets are discarded.
Alternatively, the packet length is minimized to the specified frame length. This parameter takes
effect only when the packet enters the port rather than when the packet that exits the port.
Values
Valid Values
1518-9600
Configuration Guidelines
Set the value as required. Generally, select the default value, unless otherwise specified.
Issue 02 (2011-06-30)
labels. Connecting to the port at the network side, an S-Aware port identifies and processes
the packets with S-VLAN tags. The configuration examples are described as follows:
– Add the S-VLAN tag to the service from Port A to Port B, and remove the S-VLAN
tag from the service from Port B to Port A. Then select C-Aware for Port A, and S-
Aware for Port B.
– Configure a service from Port A to Port B to transparently transmit the C-VLAN tags
at the client side. Then select C-Aware for Ports A and B.
– Configure a service from Port A to Port B to transparently transmit the S-VALN tags
at the network side. Then select S-Aware for Ports A and B.
– Configure a service from Port A to Port B to switch the C-VLAN tags at the client side.
Then select C-Aware for Ports A and B.
– Configure a service from Port A to Port B to switch the S-VALN tags at the network
side. Then select S-Aware for Ports A and B.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Default Value
1522
7 List of Parameters
Unit
Byte
7-7