4 Configuring Ethernet Services
Field
Bound Path
Bound Path Count
4.12.2 Configuring Ethernet Private Network Services
This section describes the parameters for configuring Ethernet private network services.
Table 4-44
Table 4-44 Parameters for configuring Ethernet private network services
Field
Board
VB ID
VB Name
Bridge Type
Bridge Switch Mode
4-150
Value Range
For example: VC4-4-VC12(1-2,4)
For example: 3
lists the parameters that are used for configuring Ethernet private network services.
Value Range
NE Name-Slot ID-Board
Name
For example: NE(9-1)-4-
EFS8
For example: 1
Contains up to 16
characters or numerals in
English or eight
characters in Chinese.
For example: VB1
802.1q, 802.1d, 802.1ad
Default value: 802.1q
IVL/Ingress Filter
Enable, SVL/Ingress
Filter Disable
Default value: IVL/
Ingress Filter Enable
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OptiX OSN 550 Multi-Service CPE Optical Transmission
Description
Displays the name of the board.
The VB ID is allocated automatically
when you create a LAN service.
Specifies the name of the VB.
Specifies the type of the VB.
Specifies the switching mode of the VB.
System
Configuration Guide
Description
Specifies the
number of a path to
be bound, including
the numbers of the
VC-4, VC-12 or
VC-3, and GE
paths.
Displays the
number of bound
paths.
Issue 02 (2011-06-30)