Lpt; Bearer Mode - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

7 List of Parameters

7.90 LPT

Description
The LPT parameter specifies whether the link state pass through (LPT) function is enabled. The
LPT is a technology developed by Huawei to increase the speed of the link state response.
Through the LPT protocol, the faults on the service access point and in the intermediate network
can be detected and reported.
Impact on the System
When the LPT function is enabled, the faults on the service access point and in the intermediate
network can be detected and reported. For example, the service access point can be informed of
the fault in the intermediate network and thus can handle the fault accordingly (switch the service
to the backup link). When the LPT function is disabled, the link fault in the intermediate network
is not reported to the service access point.
Values
Value Range
Yes, No
The following table provides the description of each value.
Value
Yes
No
Configuration Guidelines
Set this parameter according to the actual requirement of the user. Set this parameter to Yes if
the LPT function is required.

7.91 Bearer Mode

Description
The Bearer Mode parameter specifies the frame format of the LPT protocol packet for
transmission. Three bearer modes are available, namely, GFP (HUAWEI), Ethernet, and GFP
(CSF).
7-74
OptiX OSN 550 Multi-Service CPE Optical Transmission
Description
Indicates that the LPT function is enabled.
Indicates that the LPT function is disabled.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Default Value
No
System
Configuration Guide
Issue 02 (2011-06-30)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents