Flow Of Configuring Eplan Services - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Step
Operation
2
Configuring Internal Ports on Ethernet
Boards
3
Creating EPL Services
4
Creating SDH Services
5
Configuring QoS
6
Testing Ethernet Service Channels
7
Setting Performance Monitoring
Parameters of an NE
8
Backing Up the NE Database to the
SCB Board

4.3.3 Flow of Configuring EPLAN Services

EPLAN services provide the customers with Layer 2 switching-based multipoint-connected
LAN services.
The Ethernet switching boards are required for configuring EPLAN services. The Ethernet
switching boards that support EPLAN services are provided in
Issue 02 (2011-06-30)
Remarks
Required
When an NE transmits Ethernet services through the internal
ports (that is, VCTRUNK ports) on the Ethernet board to the
SDH side, you need to configure the attributes of the
VCTRUNK ports so that the VCTRUNK ports can work with
the Ethernet board on the opposite equipment. This ensures
that the transmission of the Ethernet services in the SDH
network is normal.
Required
When an Ethernet switching board carries private line
services, the relevant information of the private line services,
such as the service source and service sink, must be specified.
Required
This topic describes how to create the timeslot connections
between the bound paths and the line board, thus ensuring that
the Ethernet services are transmitted in specified timeslots
over the transmission line.
Optional
The services of different users need to share the bandwidth. If
the services of different users need to be configured with
different quality levels, you need to adopt the corresponding
QoS scheme.
Required
After the Ethernet services are created, test the service
continuity.
Required
Enable the performance monitoring function for a specific NE.
Then, you can obtain detailed performance records during the
operation process of this NE. These records can be used for
monitoring and analyzing the running status of this NE.
Required
Back up the NE database to ensure that the NE can be
automatically recovered to normal operation after the SCC
data is lost or after the equipment is powered off.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Configuring Ethernet Services
Table
6-1.
4-27

Hide quick links:

Advertisement

Table of Contents
loading