Huawei OptiX OSN 550 Configuration Manual page 283

Multi-service cpe optical transmission system
Table of Contents

Advertisement

OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Issue 02 (2011-06-30)
User
Paramete
r
Sink Slot
Sink VC4
Sink
Timeslot
Range(e.g.
1,3-6)
Activate
Immediatel
y
User N
Level
Direction
Source Slot 4-EFS8-1
Source
VC4
Source
Timeslot
Range(e.g.
1,3-6)
Sink Slot
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Value in
Description
This
Example
6-SL4D-1
When you create a bidirectional SDH
(SDH-1)
service from an Ethernet board to a line
board, it is recommended that you set the
slot of the line board as the sink slot.
VC4-1
In this example, VC4-1 is specified as the
VC-4 timeslot of the Ethernet service on the
line board.
1-30
The value range of the sink timeslots can be
the same as or different from the value
range of the source timeslots. The number
of sink timeslots must be, however,
consistent with the number of sink
timeslots.
Yes
-
VC12
The timeslot bound with the service of user
N is at the VC-12 level. The service level
must be consistent with the level of the path
bound with the VCTRUNK.
Bidirectiona
The service of user N is a bidirectional
l
service.
When you create a bidirectional SDH
(SDH-1)
service from an Ethernet board to a line
board, it is recommended that you set the
slot of the Ethernet board as the source slot.
VC4-4
The value range of Source VC4 is
consistent with the value range of
Available Resources, which is set for the
paths bound with VCTRUNK2. In the case
of VCTRUNK2, Available Resources is
set to VC4-4.
31-60
The value range of the source timeslots is
consistent with the value range of
Available Timeslot, which is set for the
paths bound with VCTRUNK2. In the case
of VCTRUNK2, the value of Available
Timeslot is from VC12-31 to VC12-60.
6-SL4D-1
When you create a bidirectional SDH
(SDH-1)
service from an Ethernet board to a line
board, it is recommended that you set the
slot of the line board as the sink slot.
4 Configuring Ethernet Services
4-129

Hide quick links:

Advertisement

Table of Contents
loading