7 List of Parameters
Values
Valid Values
1-120, in step length of 1
Configuration Guidelines
Generally, select the default value, unless otherwise specified. Otherwise, set the value according
to the requirements. Do not set the value beyond the range allowed by the board.
Relationship with Other Parameters
None.

7.96 Frames to Send

Description
Frames to Send indicates the number of test packets to be transmitted. With this parameter
enabled, the system transmits a test packet at the intervals of certain period of time until the
number of transmitted test packets reaches the specified value.
Impact on the System
The system operation is not affected.
Values
Value Range
0-255
Configuration Guidelines
The user can set the number of test packets to be transmitted as required.
Relationship with Other Parameters
This parameter is valid only when Send Mode is set to Burst Mode.

7.97 Status

Description
Status indicates the transmit status of the current test frames at the port. This parameter is
displayed as the current test status after you configure Send Mode and Frames to Send and
then click Apply.
7-78
OptiX OSN 550 Multi-Service CPE Optical Transmission
Default Value
8
Default Value
0
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
System
Configuration Guide
Unit
Min
Unit
Unit