Huawei OptiX OSN 550 Configuration Manual page 290

Multi-service cpe optical transmission system
Table of Contents

Advertisement

4 Configuring Ethernet Services
Field
Traffic Threshold(Mbit/s)
Port Traffic Threshold Time
Window(Min)
Loop Detection
Loop Port Shutdown
4-136
OptiX OSN 550 Multi-Service CPE Optical Transmission
Value Range
0-100 (FE), 0-1000 (GE), in
step length of 1
Default value: 100 (FE),
1000 (GE)
0-30
Default value: 0
Enabled, Disabled
Default value: Disabled
Enabled, Disabled
Default value: Enabled
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
System
Configuration Guide
Description
The Traffic Threshold
(Mbit/s) (External
Ethernet Port Attribute)
parameter specifies the data
flow threshold at external
physical ports.
You can click
7.10 Traffic
Threshold(Mbit/s)
(External Ethernet Port
Attribute)
to display the
detailed information.
The Port Traffic
Threshold Time Window
(Min) parameter specifies
the duration for a
VCTRUNK or a IP port to
monitor the traffic after the
zero traffic monitoring
function of the port is
enabled.
You can click
7.14 Port
Traffic Threshold Time
Window(Min)
to display
the detailed information.
The Loop Detection
(Ethernet Port Attribute)
parameter specifies the
function of reporting the
self-loop alarms after one
of the following loopback
cases is detected.
You can click
7.8 Loop
Detection (Ethernet Port
Attribute)
to display the
detailed information.
The Traffic Threshold
(Mbit/s) (External
Ethernet Port Attribute)
parameter specifies the data
flow threshold at external
physical ports.
You can click
7.9 Loop
Port Shutdown (Ethernet
Port Attribute)
to display
the detailed information.
Issue 02 (2011-06-30)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents