3 Configuring SDH Services
Step 4 Enable the performance monitoring function for NEs. For details, see Setting Performance
Monitoring Parameters of an NE.
Step 5 Back up the configuration data of the NEs. For details, see Backing Up the NE Database to the
SCB Board.
----End
Relevant Task
To delete any service that is incorrectly configured, see Deleting SDH Services.

3.11 Protection Configuration Parameters

You need to set the necessary parameters when configuring the protection such as MSP, SNCP
for an NE.

3.11.1 SNCP Configuration

You need to set the necessary parameters when configuring the SNCP for an NE.
3.11.2 Configuring the Multiplex Section Protection
You need to set the necessary parameters when configuring the multiplex section protection
(MSP).
3.11.1 SNCP Configuration
You need to set the necessary parameters when configuring the SNCP for an NE.
Table 3-1

Table 3-1 Parameters for configuring the SNCP

Field
Service Type
Revertive Mode
3-68
lists the parameters for configuring the SNCP.
Value
SNCP
Non-Revertive, Revertive
Default: Non-revertive
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
OptiX OSN 550 Multi-Service CPE Optical Transmission
System
Configuration Guide
Description
Specifies the type of the new
SNCP service.
Specifies whether the services
can be switched from the
protection channel to the
working channel after the
working channel is restored.
If you set this field to
Revertive, the services can be
switched from the protection
channel to the working
channel. If you set this
parameter to Non-Revertive,
the services cannot be
switched from the protection
channel to the working
channel.