B1 Ber Threshold-Crossing Generated - Huawei OptiX OSN 550 Configuration Manual

Multi-service cpe optical transmission system
Table of Contents

Advertisement

7 List of Parameters

7.120 B1 BER Threshold-Crossing Generated

Description
The B1 BER Threshold-Crossing Generated parameter is used to specify whether a B1 BER
threshold-crossing alarm is a condition for triggering clock source switching. B1 BER
Threshold-Crossing alarm is an index for measuring the performance of clock source signals.
Impact on the System
The system running is not affected.
Values
Value Range
Yes, No
The following table lists the description of each value.
Value
Yes
No
Configuration Guidelines
A B1 BER threshold-crossing alarm indicates that the transmitted signal and the clock in the
signal are being interfered. Therefore, this parameter can be set as a condition for triggering
clock source switching in actual application to ensure system performance.
Relationship with Other Parameters
None.
Related Information
None.
7-98
OptiX OSN 550 Multi-Service CPE Optical Transmission
Default Value
No
Description
Indicates that a B1 BER threshold-crossing alarm is the
sufficient condition for triggering clock source switching.
Indicates that a B1 BER threshold-crossing alarm is not the
condition for triggering clock source switching.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
System
Configuration Guide
Issue 02 (2011-06-30)