Fujitsu M10 Installation Manual page 121

Hide thumbs Also See for M10:
Table of Contents

Advertisement

Figure 3-41     Removing a rail pin
5.
Remove the one screw (A in
The removed screw will be used in step 8.
Figure 3-42     Screws on the sides of rails
A
FRONT
FRONT
6.
Attach the rail to the rack.
Attach the rail such that the spring-loaded side (B in
and the flange (C in
a. From the front of the rack, insert the rail protrusions into 2U top and 1U top
in the front supporting column of the rack.
b. Pull out the rail to as far as the depth of the rack.
c. Insert the rail protrusions into 2U top and 1U bottom in the rear supporting
column of the rack.
d. Secure the rail with one M6 screw to the front supporting column of the rack.
The fixing location is 2U bottom.
e. Attach the other rail in the same manner.
A
B
Figure
3-42) from the side of the rail.
A
B
C
Figure
3-42) faces the bottom.
FRONT
FRONT
Figure
3-42) faces the front
Chapter 3 Installing the System
107