Maintenance/Addition Menu
Please select the chassis including added FRU.
No. FRU Status
--- ------------------- --------------
1 /BB#0 Normal
2 /BB#1 Normal
3 /BB#2 Unmount
4 /BB#3 Unmount
------------------------------------------------------------------------------
Select [1,2|c:cancel] : c
4.
Diagnose the installed SPARC M10-4S.
a. Execute the testsb command to perform a diagnosis test.
XSCF> testsb -v -p -s -y XX-Y
XSCF> testsb -v -p -s -y 01-0
Initial diagnosis is about to start, Continue?[y|n] :y
SB#01-0 power on sequence started.
b. From the master XSCF, check the cables between the installed chassis and
XSCF> diagxbu -y -b xx -p yy
Specify the PSB number of the diagnosis target PSB in XX-Y. XX is a BB-ID,
and Y is fixed at 0.
An initial diagnosis and connection I/O check are performed on the diagnosis
target PSB.
<Description of options specified>
-v: Additionally displays detailed messages of the initial diagnosis
-p: Executes the "probe-scsi-all" command of OpenBoot PROM and displays
the results while a diagnosis is being processed
-s: Executes the "show-devs" command of OpenBoot PROM and displays the
results while a diagnosis is being processed
-y: Automatically responds with "y" to a query
The following example performs a diagnosis test on the installed BB#01.
If an error is displayed, see
the physical partition that is the incorporation destination.
Execute the diagxbu command to check the cables.
Specify the BB-ID of the installed BB in XX. Specify the PPAR-ID of the
incorporation destination in YY.
The following example performs a diagnosis between the installed BB#01 and
incorporation-destination PPAR#0.
Chapter 9 Installing a System with a Building Block Configuration
"A.2.4 Checking diagnosis
results."
245