Figure 5-14     Handling of power cords
2.
First, store any interface cables other than crossbar cables (electrical). Then,
store the crossbar cables (electrical).
a. Store the LAN cables and I/O cables connected as described in Chapter 5 in an
empty space at the right side as viewed from the rear of the rack.
b. Store the XSCF cable connected as described in Chapter 4 in an empty space
at the right side as viewed from the rear of the rack.
c. Store the crossbar cables connected as described in Chapter 4 in an empty
space on the right side, as viewed from the rear of the rack.
  Cables fit neatly when stored in units of four connected cables.
Remarks - Lay the cables so that any interface cables other than crossbar cables are on the
inside side of the rack, i.e., farther inside than the crossbar cables.
Chapter 5 Connecting Cables to the Chassis
173