Figure A-4     Mistaken settings for the BB-IDs of BB#00 and BB#01
1.
Remove the power cords of all chassis from the power supply units.
2.
Disconnect the SCF cables and DUAL cables of BB#00 and BB#01.
3.
Connect the system management terminal to the serial port of BB#00, and
connect the power cords to the power supply units.
4.
Log in to the XSCF by using the default user account and authentication
method.
For details, see
5.
Execute the restoredefaults -c factory command to return the entire system to
the factory default settings.
XSCF>   restoredefaults -c factory 
 
WARNING:  
    If   this   system   does   not   have   BACK   UP,   this   command   will   set  
all   the   user  
    settable   XSCF   configuration   parameters   to   their   default   value  
as   they  
    were   set   when   the   system   was   shipped   out.  
    Furthermore,   this   command   will   delete   all   logs   in   the   intended
  chassis   XSCF.  
    Check   the   man   page   of   this   command   before   you   run   it.  
 
Continue?[yes/no](default   no): yes 
You   must   check   the   following   points.  
 
    1.   Have   the   ability   to   power   cycle   the   system.  
    2.   Have   access   to   the   serial   console   and   hold   the   serial  