If you do not use memory mirror mode, this work is not necessary.
9.
Register the system board of the installed SPARC M10-4S in the physical
partition configuration list.
a. Execute the showpcl command to check the physical partition configuration
list.
XSCF> showpcl -p 0
PPAR-ID LSB PSB Status
00 Powered off
00 00-0
01 01-0
b. Execute the setpcl command to register the system board with the physical
partition.
The following example associates system board 02-0 with logical system
board 02 of physical partition 0.
XSCF> setpcl -p 0 -a 02=02-0
c. Execute the showpcl command, and confirm the configured physical
partition.
XSCF> showpcl -p 0
PPAR-ID LSB PSB Status
00 Powered off
00 00-0
01 01-0
02 02-0
10. Register a CPU Activation key, and assign CPU core resources.
a. Execute the showcodusage command to display the CPU Activation key
information.
The following example displays the CPU Activation key information.
XSCF> showcodusage -p resource
Resource In Use Installed CoD Permitted Status
-------- ------ --------- ------------- ------
PROC 64 64 128 OK: 64 cores available
Note - If the number of registered CPU Activation keys is insufficient for the number of CPU
cores to be used, request the customer to purchase CPU Activations to add CPU Activation
keys. For details on adding a CPU Activation key, see
key."
b. Execute the showcod command to check the CPU resource information for
the physical partition.
Chapter 9 Installing a System with a Building Block Configuration
"7.11.3 Registering a CPU Activation
257