Testing: The initial diagnosis is in progress.
Passed: The initial diagnosis ended normally.
Failed: A failure occurred in the initial diagnosis.
Fault: PSB degradation status
■
Normal: The PSB is normal.
Degraded: The PSB can operate but has a degraded component.
Faulted: The PSB is not operating because a failure occurred or cannot be
controlled because of a communication failure.
Example: SPARC M10-4 diagnosis example (normal end), including execution of
show-devs and probe-scsi-all
XSCF> testsb -v -p -s -a -y
Initial diagnosis is about to start, Continue?[y|n] :y
SB power on sequence started.
POST Sequence 01 Banner
LSB#00: POST 1.9.0 (2012/09/25 16:52)
POST Sequence 02 CPU Check
POST Sequence 03 CPU Register
POST Sequence 04 STICK Increment
POST Sequence 05 Extended Instruction
POST Sequence 06 MMU
POST Sequence 07 Memory Initialize
POST Sequence 08 Memory Address Line
POST Sequence 09 MSCAN
POST Sequence 0A Cache
POST Sequence 0B Floating Point Unit
POST Sequence 0C Encryption
POST Sequence 0D Cacheable Instruction
POST Sequence 0E Softint
POST Sequence 0F CPU Cross Call
POST Sequence 10 CMU-CH
POST Sequence 11 PCI-CH
POST Sequence 12 TOD
POST Sequence 13 MBC Check Before STICK Diag
POST Sequence 14 STICK Stop
POST Sequence 15 STICK Start
POST Sequence 16 Barrier Blade
POST Sequence 17 Single Barrier Bank
POST Sequence 18 Multi Barrier Banks
POST Sequence 19 Sector Cache
POST Sequence 1A SX
POST Sequence 1B RT
POST Sequence 1C RT/SX NC
POST Sequence 1D RT/SX Interrupt
POST Sequence 1E RT/SX Barrier
POST Sequence 1F Error CPU Check
POST Sequence 20 System Configuration
POST Sequence 21 System Status Check
POST Sequence 22 Start Hypervisor
POST Sequence Complete.
Post APL Hypervisor version: @(#)Hypervisor 0.19.4 2012/09/24 18:12