XSCF>   diagxbu -y -b 0 -t 1 
XBU   diagnosis   is   about   to   start,   Continue?[y|n]   :y
Step   1(total   3   steps)   started.   [1800sec]
0.....   30.....   60.....   90.....120end
completed.
.
.
Step   3(total   3   steps)   started.   [1200sec]   0.....   30.....   60.....   90.....120end
completed.
*Note*
Please   confirm   the   error   of   XBU   by   "showlogs   error".
In   addition,   please   confirm   the   degraded   of   XBU   by   "showstatus".
XSCF>
A.3
How to Restore a BB-ID from an
Incorrect Setting
If a BB has an incorrectly set BB-ID, it does not start up normally when the input
power is turned on. This section describes the procedures for restoring a BB-ID.
A.3.1
BB-IDs not set (BB-ID 00)
If all BB-IDs have been left as 00 without being set when the input power is turned
on, restore them according to the following procedure.
 