*Note*
This   command   only   issues   the   instruction   to   power-on.
The   result   of   the   instruction   can   be   checked   by   the
  "showpparprogress".
Note - In the SPARC M10-1, a physical partition takes about 5 minutes to start. In the SPARC
M10-4, it takes about 7 minutes. In the SPARC M10-4S in the 4BB configuration, it takes
about 25 minutes.
3.
Execute the showpparprogress command.
You can check the progress, in the midst of processing, between physical
partition power-on and up to before the start of POST.
Confirm that the command displays "The sequence of power control is
completed." and ends.
Note - Oracle Solaris does not start automatically because the auto-boot? setting is false.
XSCF>   showpparprogress -p 0
PPAR   Power   On   Preprocessing   PPAR#0   [   1/12]
PPAR   Power   On                               PPAR#0   [   2/12]
XBBOX   Reset                                   PPAR#0   [   3/12]
PSU   On                                             PPAR#0   [   4/12]
CMU   Reset   Start                           PPAR#0   [   5/12]
XB   Reset   1                                     PPAR#0   [   6/12]
XB   Reset   2                                     PPAR#0   [   7/12]
XB   Reset   3                                     PPAR#0   [   8/12]
CPU   Reset   1                                   PPAR#0   [   9/12]
CPU   Reset   2                                   PPAR#0   [10/12]
Reset   released                             PPAR#0   [11/12]
CPU   Start                                       PPAR#0   [12/12]
The   sequence   of   power   control   is   completed.
XSCF>
4.
Execute the showdomainstatus command, and confirm that status is
"OpenBoot Running".
XSCF#   showdomainstatus -p 0 
Logical   Domain   Name       Status  
primary                               OpenBoot   Running  
XSCF#  
5.
Execute the console command to connect to the console of the specified
physical partition.
The auto-boot? setting is false, so you can confirm the start up to the ok prompt.