6.2.2

Turning on the input power and starting the XSCF

1.
Set the mode switch on the operation panel to the Service position. For a
building block configuration, set the mode switches on the master chassis
and the chassis that has the standby XSCF to the Service position.
The Service position is indicated by a wrench icon. The Locked position is
indicated by a lock icon.
Note - Set the master chassis and the chassis that has the standby XSCF to the same mode. If
their settings are different, an asterisk (*) is shown beside the components in the output of
the showhardconf or showstatus command.
Remarks - In a building block configuration with direct connections between chassis, change
the mode switches of BB-ID#00 and #01 to Service mode. In a building block configuration
with connections through crossbar boxes, change the mode switches of BB-ID#80 and #81 to
Service mode.
Figure 6-1     Mode switch on the operation panel of the SPARC M10-1
Service
Chapter 6 Performing an Initial System Diagnosis
Locked
179