b. Execute the diagxbu command to check the cables.
XSCF>   diagxbu -y -b XX   -t  YY     [-t   zz]  
XSCF>   diagxbu -y -b 02 -t 00 -t 01
XBU   diagnosis   is   about   to   start,   Continue?[y|n]   :y  
Power   on   sequence   started.   [7200sec]  
    0.....   30.....   60.....   90..end  
XBU   diagnosis   started.   [7200sec]  
    0.....   30.....   60.....   90.....120.....150.....180.....210.....240.....|  
270.....300.....330.....360.....390.....420.....450.....480.....510.....\  
540.....570.....600.....630.....660.....690.....720.....750.....780.....|  
810.....840.....870.....900.....930.....960.....990.....1020.....1050.....\  
1080.....1110...end  
completed.  
Power   off   sequence   started.   [1200sec]  
    0.....   30.....   60.....   90.....120.....150.....180.....210...end  
completed.
c. Execute the showlogs error command, and confirm that no error is displayed.
XSCF>   showlogs error
d. Execute the showhardconf command to check the configuration, status,
7.
If the installation expanded the 1BB configuration to a multiple-BB configuration,
configure the XSCF network.
For details, see
Setting a takeover IP
After configuration, execute the applynetwork command to apply the settings,
and confirm that they were reflected. Then, execute the rebootxscf command to
complete settings, and go to the next step. For details on the procedure, see
"7.5.6 Applying network
Since you are expanding the 2BB configuration to the 3BB configuration, this
work is not necessary.
8.
To configure memory mirroring for the installed SPARC M10-4S, set memory
mirror mode.
For details, see
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015
256
Specify the BB-ID of the installed BB in XX. (*2) indicates this BB-ID checked
in step b.
In YY, specify the BB-ID of the BB incorporated into the physical partition.
(*1) indicates this BB-ID checked in step b.
The following example performs a diagnosis between the installed BB#02 and
the incorporated BB#00 and BB#01 in PPAR#0.
If an error is displayed, see
and quantities.
For details, see
"6.8 Checking the Component
"7.5.2 Setting an Ethernet (XSCF-LAN) IP
address."
"7.6 Configuring Memory
"A.2.2 Checking the contents of
settings."
Mirroring."
logs."
Status."
address" and
"7.5.3