Checking The Component Status - Fujitsu M10 Installation Manual

Hide thumbs Also See for M10:
Table of Contents

Advertisement

----   -------   --------
00-0   Passed     Normal
01-0   Passed     Normal
02-0   Passed     Normal
03-0   Passed     Normal
 
XSCF>
2.
Check the execution results of "probe-scsi-all" to confirm that all mounted
internal disks are identified.
3.
Check the execution results of "show-devs" to confirm that all mounted PCIe
cards are identified.
4.
Confirm that "Passed" and "Normal" appear for all PSBs in the results from
the initial diagnosis.
If the results display anything other than the above, see
Troubleshooting."
6.8

Checking the Component Status

This section describes the procedure for checking the configuration, status, and
quantities of the mounted field replaceable units (FRUs).
1.
Execute the showhardconf command.
The command displays all the FRUs mounted in the chassis and their status.
However, it does not display the status of I/O-related components such as PCI
cards and PCI expansion units while the system power is off.
Example: SPARC M10-1 display example
XSCF>   showhardconf -M
SPARC   M10-1;
        +   Serial:21xxxxxxxx;   Operator_Panel_Switch:Service;
        +   System_Power:Off;   System_Phase:Cabinet   Power   Off;
        Partition#0   PPAR_Status:Powered   Off;
        MBU   Status:Normal;   Ver:2209h;   Serial:TZ01348006     ;
                +   FRU-Part-Number:CA07363-D011   A0       /7088702                             ;
                +   Power_Supply_System:   ;
                +   Memory_Size:1024   GB;   Type:   B   ;     (*1)
                CPU#0   Status:Normal;   Ver:4141h;   Serial:00010263;
                        +   Freq:3.200   GHz;   Type:0x20;     (*2)
                        +   Core:16;   Strand:2;                   (*3)
                MEM#00A   Status:Normal;
                        +   Code:ce8001M386B8G70BO0-YH94   0000-2151EFEB;
                        +   Type:47;   Size:64   GB;
                MEM#01A   Status:Normal;
                        +   Code:ce8001M386B8G70BO0-YH94   0000-2151EF8A;
                        +   Type:47;   Size:64   GB;  
 
                          Omitted
Chapter 6 Performing an Initial System Diagnosis
"Appendix A
189