00-0 Passed Normal
01-0 Passed Normal
02-0 Passed Normal
03-0 Passed Normal
XSCF>
2.
Check the execution results of "probe-scsi-all" to confirm that all mounted
internal disks are identified.
3.
Check the execution results of "show-devs" to confirm that all mounted PCIe
cards are identified.
4.
Confirm that "Passed" and "Normal" appear for all PSBs in the results from
the initial diagnosis.
If the results display anything other than the above, see
Troubleshooting."
6.8
Checking the Component Status
This section describes the procedure for checking the configuration, status, and
quantities of the mounted field replaceable units (FRUs).
1.
Execute the showhardconf command.
The command displays all the FRUs mounted in the chassis and their status.
However, it does not display the status of I/O-related components such as PCI
cards and PCI expansion units while the system power is off.
Example: SPARC M10-1 display example
XSCF> showhardconf -M
SPARC M10-1;
+ Serial:21xxxxxxxx; Operator_Panel_Switch:Service;
+ System_Power:Off; System_Phase:Cabinet Power Off;
Partition#0 PPAR_Status:Powered Off;
MBU Status:Normal; Ver:2209h; Serial:TZ01348006 ;
+ FRU-Part-Number:CA07363-D011 A0 /7088702 ;
+ Power_Supply_System: ;
+ Memory_Size:1024 GB; Type: B ; (*1)
CPU#0 Status:Normal; Ver:4141h; Serial:00010263;
+ Freq:3.200 GHz; Type:0x20; (*2)
+ Core:16; Strand:2; (*3)
MEM#00A Status:Normal;
+ Code:ce8001M386B8G70BO0-YH94 0000-2151EFEB;
+ Type:47; Size:64 GB;
MEM#01A Status:Normal;
+ Code:ce8001M386B8G70BO0-YH94 0000-2151EF8A;
+ Type:47; Size:64 GB;
Omitted