it so that all the versions are the same.
1.
Execute the version command.
The command comprehensively displays the version.
In a building block configuration of the M10-4S, you can check which is the
master/standby.
XSCF>   version -c xcp
BB#00-XSCF#0   (Master)
XCP0   (Current):   2042
XCP1   (Reserve):   2042
BB#01-XSCF#0   (Standby)
XCP0   (Current):   2042
XCP1   (Reserve):   2042
BB#02-XSCF#0
XCP0   (Current):   2042
XCP1   (Reserve):   2042
BB#03-XSCF#0
XCP0   (Reserve):   2042
XCP1   (Current):   2042
The following example shows a building block configuration of the M10-4S.
Here, BB#02 has a different XCP version, so it must be updated to match the
version. Perform step 2 and subsequent steps.
XSCF>   version -c xcp
BB#00-XSCF#0   (Master)
XCP0   (Current):   2042
XCP1   (Reserve):   2042
BB#01-XSCF#0   (Standby)
XCP0   (Current):   2042
XCP1   (Reserve):   2042
BB#02-XSCF#0
XCP0   (Current):   2041       *   Different   version
XCP1   (Reserve):   2041
BB#03-XSCF#0
XCP0   (Reserve):   2042
XCP1   (Current):   2042
2.
If the XCP version of a chassis differs, execute the flashupdate -c sync
command to update the XCP version on that chassis.
The command matches the firmware version with the version on the master
XSCF.
XSCF>   flashupdate -c sync
XCP   update   is   started.   [3600sec]  
    0.....   30.....   60.....   90.....120.....150.....180.....
210.....240.....
270.....300.....330.....360.....390.....420.....450.....480.....
510.....
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015