console   of   the  
          XSCF   to   confirm   the   completion   of   the   command.  
 
If   you   answer   "yes"   this   command   will   HALT   the   XSCF   when   it  
completes.  
You   will   need   to   power   cycle   the   system   after   the   XSCF   BOOT  
STOP.  
 
Do   you   really   want   to   continue?  
 
Continue?[yes/no](default   no):yes  
The   initialization   of   XSCF   will   be   started.  
    XSCF         :   all   data   clear   (exclude   SYSTEM   ID   data)  
    BACK   UP   :   all   data   clear   (exclude   SYSTEM   ID   data)  
XSCF   will   be   automatically   rebooted.   Afterwards,   XSCF   will   be  
initialized.  
Continue?[yes/no](default   no):yes  
Disabling   IDIAG   prompt   complete  
Setting   FRUID-ROM   to   writable   complete  
Clear   BB-ID   complete  
Backup   common   DB   complete  
Syncing   file   systems...     complete  
XSCF   shutdown   request   was   completed.  
6.
Confirm that all LEDs on the operation panel are off.
7.
Remove the power cords from the power supply units.
8.
Change the BB-IDs to the correct settings.
For details, see
"4.1 Setting the ID (BB-ID) Identifying a
9.
Perform steps 3 to 8 for BB#01.
10. Connect the SCF cables and DUAL cables of BB#00 and BB#01.
11. Connect the power cords of all chassis to the power supply units.
12. Connect the system management terminal to the serial port of the master
XSCF.
13. Proceed with work by returning to
Chassis."
"6.3 Logging In to the
Appendix A Troubleshooting
XSCF."