XSCF> diagxbu -y -b 01 -p 00
XBU diagnosis is about to start, Continue?[y|n] :y
Power on sequence started. [7200sec]
0..... 30..... 60..end
XBU diagnosis started. [7200sec]
0..... 30..... 60..... 90.....120.....150.....180.....210.....240...../
270.....300.....330.....360.....390.....420.....450.....480.....510.....\
540.....570.....600.....630.....660.....690.....720.....750.....780.....\
810.....840.....870.....900.....930...end
completed.
Power off sequence started. [1200sec]
0..... 30..... 60..... 90.....120.....150.....180.end
completed.
c. Execute the showlogs error command, and confirm that no error is displayed.
XSCF> showlogs error
If an error is displayed, see
d. Execute the showhardconf command to check the configuration, status,
5.
The installation expands the 1BB configuration to a multiple-BB configuration.
So, configure the XSCF network.
For details, see
Setting a takeover IP
After configuration, execute the applynetwork command to apply the settings,
and confirm that they were reflected. Then, execute the rebootxscf command to
complete settings, and go to the next step. For details on the procedure, see
"7.5.6 Applying network
6.
To configure memory mirroring for the installed SPARC M10-4S, set memory
mirror mode.
For details, see
If you do not use memory mirror mode, this step is not necessary.
7.
Register the system board of the installed SPARC M10-4S in the physical
partition configuration list.
a. Execute the showpcl command to check the physical partition configuration
XSCF> showpcl -p 0
PPAR-ID LSB PSB Status
00 Running
00 00-0
b. Execute the setpcl command to register a system board in the physical
Fujitsu M10/SPARC M10 Systems Installation Guide ・ July 2015
246
and quantities.
For details, see
"6.8 Checking the Component
"7.5.2 Setting an Ethernet (XSCF-LAN) IP
address."
"7.6 Configuring Memory
list.
partition configuration list.
"A.2.2 Checking the contents of
settings."
Mirroring."
logs."
Status."
address" and
"7.5.3