Inspecting, Maintaining, and Testing the Battery (continued)
Charging the Battery
Groundsmaster 360
16225SL Rev C
H. Use the
Minimum Voltage Table (page
voltage for the center cell electrolyte temperature reading.
Minimum Voltage Table
Minimum Voltage
9.6
9.5
9.4
9.3
9.1
8.9
8.7
8.5
I.
If the test voltage is below the minimum, replace the battery. If the test
voltage is at or above the minimum, return the battery to service.
4. After you make the connections, apply terminal protector (Toro Part No.
107-0392) or a light layer of grease on all the battery posts and cable
connectors to reduce corrosion.
To minimize damage to the battery and allow the battery to charge fully, do the
following slow charging procedure. You can do this charging procedure with a
constant current battery charger that is locally available.
Follow the manufacturer's instructions when using a battery charger.
Note: Using specific gravity of the battery cells is the most accurate procedure
of determining the battery condition.
1. Determine the battery charge level from either its specific gravity or open
circuit voltage.
Battery Charge Level
100%
75%
50%
25%
0%
Battery-Electrolyte Temperature
70°F (and up)
60°F
50°F
40°F
30°F
20°F
10°F
0°F
IMPORTANT
Specific Gravity
1.265
1.225
1.190
1.155
1.120
Page 5–113
5–113), determine the minimum
21.1°C (and up)
16°C
10°C
4°C
-1°C
-7°C
-12°C
-18°C
Open Circuit Voltage
12.68
12.45
12.24
12.06
11.89
Electrical System: Service and Repairs

Advertisement

Table of Contents
loading

Table of Contents