Toro Groundsmaster 360 Service Manual page 350

4-wheel drive models with yanmar engine
Hide thumbs Also See for Groundsmaster 360:
Table of Contents

Advertisement

Charging the Battery (continued)
Electrical System: Service and Repairs
2. Determine the charging time and rate using the manufacturer's battery
charger instructions or the following
Battery Charge Level Table
Battery
Reserve
75%
Capacity
(Minutes)
80 or less
3.8 hrs
81 to 125
5.3 hrs
126 to 170
5.5 hrs
171 to 250
5.8 hrs
above 250
6 hrs
10 A
Charging a frozen battery can cause explosion and can cause
personal injury. Let the battery warm to 15.5°C (60°F) before
connecting to a charger.
• Charge the battery in a well-ventilated place to dissipate the
gases produced from the charging.
• These gases are explosive; keep open flame and electrical
spark away from the battery. Do not smoke.
• Inhaling the battery gases can cause nausea.
• Unplug the charger from the electrical outlet before connecting
or disconnecting the charger leads from the battery posts.
3. Follow the battery charger manufacturer's instructions, connect the charger
cables to the battery posts. Ensure that you make a good connection.
4. Charge the battery following the manufacturer's instructions.
5. Occasionally check the temperature of the battery-electrolyte. If the
temperature is more than 52°C (125°F) or the electrolyte is violently gassing
or spewing, lower and temporarily stop the charging rate.
6. Three hours before the end of the charging, measure the specific gravity of a
battery cell once per hour.
Battery Charge Level Table (page
Battery Charge Level (Percent of Fully Charged)
50%
7.5 hrs
@
@
3 A
3 A
10.5 hrs
@
@
4 A
4 A
11 hrs
@
@
5 A
5 A
11.5 hrs
@
@
6 A
6 A
12 hrs
@
@
10 A
CAUTION
Page 5–114
5–114).
25%
0%
11.3 hrs
15 hrs
@
@
3 A
3 A
15.8 hrs
21 hrs
@
@
4 A
4 A
16.5 hrs
22 hrs
@
@
5 A
5 A
17.3 hrs
23 hrs
@
@
6 A
6 A
18 hrs
24 hrs
@
@
10 A
10 A
Groundsmaster 360
16225SL Rev C

Advertisement

Table of Contents
loading

Table of Contents