If you select 3 minutes or more in the log preservation interval, you can set [Recording time]. When [Recording
time] is set, log data for the specified time is saved for each log preservation interval specified. [Recording time]
can be set up to half the log preservation interval. However, when the log preservation interval is set to 10
minutes or more, [Recording time] is 3 minutes (180 seconds).
When [Recording time] is set to 0, the latest data is written to the log at regular time intervals as when log
preservation interval is specified to 2 seconds or less.
Log Start
10 min
10 min
10 min
1 min
1 min
1 min
A log file will be created during this time
Figure 18-17 Log output image when log interval is 10 minutes and recording time is 1 minute
Click the [Set] button to complete log file setup.