18.3.2.7. Current position data (the XYZ coordinate system)
The current position data of robot is displayed for each XYZ coordinate system axis.
To display the current position data (the XYZ coordinate system) all together, use the "Variable" type and set the
Robot Status Variable "P_CURR". Refer to "18.3.2.3 Variable" for details.
(1)
Click the position (block) at which the current position data is displayed (<a>). The left side of the display is
arranged in this position.
(2)
After the "Select item" window is displayed, click the [Robot information] button (<b>).
(3)
Select "Cur pos" (<c>) as the type in the "Create robot information" window.
(4)
After setting the information of the current position data (the XYZ coordinate system), click the [OK] button
(<d>).
<1>
<2>
<3>
<4>
<5>
<d>
Figure 18-35 Creating a display of the current position data (the XYZ coordinate system)
<1> Size
:
<2> axis
:
<3> Robot #
:
<4> Arrangement
:
<5> Color
:
18-428
<a>
<c>
Set the width of box in which the current position data (the XYZ coordinate system)
is displayed. A value from 1 to 16 can be set.
Select the displayed axis of the current position data (the XYZ coordinate system).
Select the robot number for which the current position data is displayed.
Select the position at which the current position data (the XYZ coordinate system)
is arranged.
Select the background color of the area where the current position data (the XYZ
coordinate system) is displayed.
<b>
When User definition screen (TB) is shown
18-428